diff options
author | Ivan Kohler <ivan-debian@420.am> | 2012-03-10 17:54:56 -0800 |
---|---|---|
committer | Ivan Kohler <ivan-debian@420.am> | 2012-03-10 17:54:56 -0800 |
commit | 0c4d2f8b768b5eb6ed51c27c5f9c482c2c2e96aa (patch) | |
tree | 8747338a125dbcaef31e96acb80dcf5794a9e7cf /torrus/xmlconfig | |
parent | 8f155ea8e7013a3876033b1ccf8d3099fce5cfc1 (diff) |
add preliminary Torrus config for Ractivity PDU devices, RT#14601
Diffstat (limited to 'torrus/xmlconfig')
-rw-r--r-- | torrus/xmlconfig/vendor/ractivity.xml | 94 |
1 files changed, 94 insertions, 0 deletions
diff --git a/torrus/xmlconfig/vendor/ractivity.xml b/torrus/xmlconfig/vendor/ractivity.xml new file mode 100644 index 000000000..64b32b6e5 --- /dev/null +++ b/torrus/xmlconfig/vendor/ractivity.xml @@ -0,0 +1,94 @@ +<?xml version="1.0"?> +<!-- + Copyright (C) 2012 Freeside Internet Services, Inc. + + File: ractivity.xml + Description: Ractivity Power Distribution Unit monitor example for Torrus. + + This program is free software; you can redistribute it and/or modify + it under the terms of the GNU General Public License as published by + the Free Software Foundation; either version 2 of the License, or + (at your option) any later version. + + This program is distributed in the hope that it will be useful, + but WITHOUT ANY WARRANTY; without even the implied warranty of + MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the + GNU General Public License for more details. + + You should have received a copy of the GNU General Public License + along with this program; if not, write to the Free Software + Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307, USA. +--> +<configuration> + + <definitions> + <def name="product" value="1.3.6.1.4.1.34097.1"/>, + <def name="name" value="1.3.6.1.4.1.34097.1.1"/>, + <def name="version" value="1.3.6.1.4.1.34097.1.2"/>, + <def name="date" value="1.3.6.1.4.1.34097.1.3"/>, + <def name="general" value="1.3.6.1.4.1.34097.2"/>, + <def name="Voltage" value="1.3.6.1.4.1.34097.2.1"/>, + <def name="MaxTotCurentTime" value="1.3.6.1.4.1.34097.2.10"/>, + <def name="TotKwh" value="1.3.6.1.4.1.34097.2.11"/>, + <def name="Intrusion" value="1.3.6.1.4.1.34097.2.12"/>, + <def name="Airflow" value="1.3.6.1.4.1.34097.2.13"/>, + <def name="Beep" value="1.3.6.1.4.1.34097.2.14"/>, + <def name="ControllerName" value="1.3.6.1.4.1.34097.2.15"/>, + <def name="RackPosition" value="1.3.6.1.4.1.34097.2.16"/>, + <def name="Frequency" value="1.3.6.1.4.1.34097.2.2"/>, + <def name="TotCurrent" value="1.3.6.1.4.1.34097.2.3"/>, + <def name="TotPower" value="1.3.6.1.4.1.34097.2.4"/>, + <def name="TemperatureInside" value="1.3.6.1.4.1.34097.2.5"/>, + <def name="HumidityInside" value="1.3.6.1.4.1.34097.2.6"/>, + <def name="MaxTotCurrentWarning" value="1.3.6.1.4.1.34097.2.7"/>, + <def name="MaxTotCurentOff" value="1.3.6.1.4.1.34097.2.8"/>, + <def name="MaxTotCurrent" value="1.3.6.1.4.1.34097.2.9"/>, + <def name="port" value="1.3.6.1.4.1.34097.3"/>, + <def name="portTable" value="1.3.6.1.4.1.34097.3.1"/>, + <def name="portEntry" value="1.3.6.1.4.1.34097.3.1.1"/>, + <def name="PortNr" value="1.3.6.1.4.1.34097.3.1.1.1"/>, + <def name="MaxCurrent" value="1.3.6.1.4.1.34097.3.1.1.10"/>, + <def name="MaxCurrentTime" value="1.3.6.1.4.1.34097.3.1.1.11"/>, + <def name="MaxCurrentWarning" value="1.3.6.1.4.1.34097.3.1.1.12"/>, + <def name="MaxCurrentOff" value="1.3.6.1.4.1.34097.3.1.1.13"/>, + <def name="Priority" value="1.3.6.1.4.1.34097.3.1.1.14"/>, + <def name="DelayOn" value="1.3.6.1.4.1.34097.3.1.1.15"/>, + <def name="PortName" value="1.3.6.1.4.1.34097.3.1.1.2"/>, + <def name="Current" value="1.3.6.1.4.1.34097.3.1.1.3"/>, + <def name="RealPower" value="1.3.6.1.4.1.34097.3.1.1.4"/>, + <def name="ApparentPower" value="1.3.6.1.4.1.34097.3.1.1.5"/>, + <def name="PowerFactor" value="1.3.6.1.4.1.34097.3.1.1.6"/>, + <def name="State" value="1.3.6.1.4.1.34097.3.1.1.7"/>, + <def name="kWh" value="1.3.6.1.4.1.34097.3.1.1.8"/>, + <def name="kWhTime" value="1.3.6.1.4.1.34097.3.1.1.9"/>, + <def name="temp" value="1.3.6.1.4.1.34097.4"/>, + <def name="tempTable" value="1.3.6.1.4.1.34097.4.1"/>, + <def name="tempEntry" value="1.3.6.1.4.1.34097.4.1.1"/>, + <def name="TempNr" value="1.3.6.1.4.1.34097.4.1.1.1"/>, + <def name="Temperature" value="1.3.6.1.4.1.34097.4.1.1.2"/>, + <def name="MaxTemp" value="1.3.6.1.4.1.34097.4.1.1.3"/>, + <def name="MaxTempTime" value="1.3.6.1.4.1.34097.4.1.1.4"/>, + <def name="TempWarning" value="1.3.6.1.4.1.34097.4.1.1.5"/>, + </definitions> + + <datasources> + + <template name="PDU"> + + <param name="data-file" value="%system-id%_power.rrd" /> + <param name="data-dir" value="XXX" /> + + <leaf name="kWh"> + <param name="comment" value="KiloWatt Hours" /> + <param name="comment" value="KiloWatt Hours" /> + <param name="vertical-label" value="kWh" /> + <param name="ds-type" value="collector" /> + <param name="collector-type" value="snmp" /> + <param name="storage-type" value="rrd" /> + <param name="collector-period" value="300" /> + <param name="collector-timeoffset" value="0" /> + </leaf> + + </datasources> + +</configuration> |